FM-200 Clean Agent Fire Suppression System


FM-200 Clean Agent Fire Suppression System

FM-200, also known as HFC-227ea or Heptafluoropropane (CF₃CHFCF₃), is a halocarbon-based clean agent fire suppression agent. Developed in accordance with TS EN 15004, ISO 14520, and NFPA 2001 standards, this system is safely used in areas containing sensitive equipment due to its colorless, odorless, and electrically non-conductive structure.

Designed for the purpose of extinguishing Class A, Class B, and Class C fires, the FM-200 system has been tested and approved by international certification bodies such as UL, FM, and LPCB. Operating on the principle of volume protection, the system activates within approximately 10 seconds after a fire is detected, brings the flames under control in a short time, and minimizes potential damage in the areas to be protected.

For the system to operate effectively, the environment to be protected must undergo a leak test. Furthermore, it is of great importance that hydraulic calculations are performed using the licensed software of the system manufacturer. Accurate engineering calculations increase suppression performance by ensuring the complete planning of cylinder capacity, piping, and nozzle placement.

FM-200 clean agent suppression systems can be safely used in occupied areas provided that proper project design is implemented. During the design phase, NOAEL and LOAEL safety limits must be considered, and the gas concentration must be calculated in accordance with international standards. Thus, both effective fire suppression is ensured and user safety is protected.

Using a lower amount of gas compared to many other clean agent suppression systems is one of the important advantages of FM-200. Thanks to its requirement for less cylinder space, providing ease of installation, and leaving no residue after suppression, it is widely preferred in data centers, electrical panels, control rooms, telecommunication infrastructures, archives, museums, and areas containing high-value electronic systems. Depending on the need, gas cylinders can be positioned inside or outside the protected area.

Application Areas

  • In IT Rooms Fire Suppression Systems

  • In Server Rooms Fire Suppression Systems

  • In Data Center Fire Suppression Systems

  • In UPS Rooms Fire Suppression Systems

  • In Battery Charging Rooms Fire Suppression Systems

  • In CCTV Camera Rooms Fire Suppression Systems

  • In LV (Low Voltage) Electrical Rooms Fire Suppression Systems

  • In MV (Medium Voltage) Electrical Rooms Fire Suppression Systems

  • In Museums Fire Suppression Systems

  • In Galleries Fire Suppression Systems

  • In Archives Fire Suppression Systems

  • In Fire Suppression Systems for Ships, Cargo, Engine Rooms, Boatswain's Stores, and Power Panels

  • In Libraries Fire Suppression Systems

  • In Transformer Substations Fire Suppression Systems

  • In Laboratories Fire Suppression Systems

  • In Fire Suppression Systems for Various Chemical Storage Areas

  • In Tunnel, Train, Metro, and Airport Control Rooms Fire Suppression Systems

  • In Cable Galleries Fire Suppression Systems

  • In GSM Link Stations and Cabinets Fire Suppression Systems

  • In Natural Gas Distribution Stations Fire Suppression Systems

  • In Vaults, ATM Systems, and Bank Cash-in-Transit Vehicles Fire Suppression Systems

  • Used in Fire Suppression Systems for Military Facilities, Communication Systems, Tanks, and Armored Vehicles.

Bu çözüm hakkında daha fazla bilgiye mi ihtiyacınız var?